Age | Commit message (Collapse) | Author | Files | Lines |
|
The bugs have been fixed,
https://github.com/rust-lang/futures-rs/pull/2801 and
https://github.com/rust-lang/futures-rs/pull/2812 were merged and ended
up in that release.
Change-Id: Iefd990d2d1719b884504093343e54e9c5258e2e2
Reviewed-on: https://cl.tvl.fyi/c/depot/+/10414
Reviewed-by: raitobezarius <tvl@lahfa.xyz>
Autosubmit: flokli <flokli@flokli.de>
Tested-by: BuildkiteCI
|
|
With the recent introduction of the RootNodes trait, there's nothing in
the fs module pulling in tvix-store dependencies, so it can live in
tvix-castore.
This allows other crates to make use of TvixStoreFS, without having to
pull in tvix-store.
For example, a tvix-build using a fuse mountpoint at /nix/store doesn't
need a PathInfoService to hold the root nodes that should be present,
but just a list.
tvix-store now has a pathinfoservice/fs module, which contains the
necessary glue logic to implement the RootNodes trait for a
PathInfoService.
To satisfy Rust orphan rules for trait implementations, we had to add a
small wrapper struct. It's mostly hidden away by the make_fs helper
function returning a TvixStoreFs.
It can't be entirely private, as its still leaking into the concrete
type of TvixStoreFS.
tvix-store still has `fuse` and `virtiofs` features, but they now simply
enable these features in the `tvix-castore` crate they depend on.
The tests for the fuse functionality stay in tvix-store for now, as
they populate the root nodes through a PathInfoService.
Once above mentioned "list of root nodes" implementation exists, we
might want to shuffle this around one more time.
Fixes b/341.
Change-Id: I989f664827a5a361b23b34368d242d10c157c756
Reviewed-on: https://cl.tvl.fyi/c/depot/+/10378
Autosubmit: flokli <flokli@flokli.de>
Tested-by: BuildkiteCI
Reviewed-by: sterni <sternenseemann@systemli.org>
|
|
The simple filesystem `BlobService` enable a user to write blob store
on an existing filesystem using a prefix-style layout in the provided root directory,
e.g. the two first bytes of the blake3 hashes are used as directories prefixes.
Change-Id: I3451a688a6f39027b9c6517d853b95a87adb3a52
Reviewed-on: https://cl.tvl.fyi/c/depot/+/10071
Autosubmit: raitobezarius <tvl@lahfa.xyz>
Tested-by: BuildkiteCI
Reviewed-by: flokli <flokli@flokli.de>
|
|
It's been a while since the last sled release, and that one binds to a
pretty old version of zstd, requiring workarounds like cl/10090.
Upstream sled main branch currently has zstd halfway patched out (it's
a no-op, but the feature flag and options are still there), and it's in
that state for a year.
Rather than maintaining our own fork of sled, let's just stop using the
compression feature in sled, dropping the version pin to zstd that way,
removing the need for cl/10090.
This doesn't mean we won't reintroduce per-blob compression - but we
probably just won't let sled take care of the compression, but do it
ourselves - which is necessary for more chunked blob storage anyways.
Even though we do drop the feature flag, we still need to explicitly use
use_compression(false).
Change-Id: I0e4892d29e41c76653272dc1a3625180da6fee12
Reviewed-on: https://cl.tvl.fyi/c/depot/+/10257
Autosubmit: flokli <flokli@flokli.de>
Reviewed-by: raitobezarius <tvl@lahfa.xyz>
Tested-by: BuildkiteCI
|
|
Change-Id: I3bea0827ec2c8db835334ce378a7bf3a39e9b1a3
Reviewed-on: https://cl.tvl.fyi/c/depot/+/9849
Tested-by: BuildkiteCI
Reviewed-by: flokli <flokli@flokli.de>
|
|
Much friendlier than either Base64 or raw byte slices.
Change-Id: I9b4cdd57c83ddc76c0be8103da4320207657a72b
Reviewed-on: https://cl.tvl.fyi/c/depot/+/9622
Reviewed-by: flokli <flokli@flokli.de>
Tested-by: BuildkiteCI
|
|
Rather than using this loop, use exponential backoff while waiting for
the socket path to be created.
Change-Id: I18706a64ce06f8916a07892dfbcd409ac5b3bff1
Reviewed-on: https://cl.tvl.fyi/c/depot/+/9568
Autosubmit: flokli <flokli@flokli.de>
Reviewed-by: Connor Brewster <cbrewster@hey.com>
Tested-by: BuildkiteCI
|
|
This bumps all these dependencies to their more recent versions.
We have to enable the `macros` tonic feature, and looks like we should
also enable `rt`, not only `rt-multi-thread`.
Change-Id: Icc3600848fca0bacce24f4889d088e75711594ef
Reviewed-on: https://cl.tvl.fyi/c/depot/+/8984
Reviewed-by: Connor Brewster <cbrewster@hey.com>
Tested-by: BuildkiteCI
Autosubmit: flokli <flokli@flokli.de>
Reviewed-by: tazjin <tazjin@tvl.su>
|
|
Similar to gen_directorysvc_grpc_client, introduce a
gen_blobsvc_grpc_client function that provides a gRPC client connected
to a blobservice.
The test is update to use that client to test against, rather than the
server trait, removing the last usage of tonic_mock, so it's removed
as well.
Fixes b/243.
Change-Id: If746e8600588da247eb53a63b70fe72f139e9e77
Reviewed-on: https://cl.tvl.fyi/c/depot/+/9564
Tested-by: BuildkiteCI
Reviewed-by: tazjin <tazjin@tvl.su>
Reviewed-by: Connor Brewster <cbrewster@hey.com>
Autosubmit: flokli <flokli@flokli.de>
|
|
- rename the feature to `tonic-reflection` in both tvix-store and tvix-
castore.
- set it to disabled in tvix-castore by default
- enable it in tvix-store, and pull in tvix-castore with the feature
enabled.
Change-Id: Ie22833d85569502cae55812f6eeb17a9c15b9e2c
Reviewed-on: https://cl.tvl.fyi/c/depot/+/9472
Autosubmit: flokli <flokli@flokli.de>
Tested-by: BuildkiteCI
Reviewed-by: raitobezarius <tvl@lahfa.xyz>
|
|
We don't use this here, except in a test, where we don't really use
it either.
Change-Id: Ia6c45fccf663fe328942b1e1a2cd1c3a1b7f9ae5
Reviewed-on: https://cl.tvl.fyi/c/depot/+/9376
Autosubmit: flokli <flokli@flokli.de>
Reviewed-by: Connor Brewster <cbrewster@hey.com>
Tested-by: BuildkiteCI
|
|
This splits the pure content-addressed layers from tvix-store into a
`castore` crate, and only leaves PathInfo related things, as well as the
CLI entrypoint in the tvix-store crate.
Notable changes:
- `fixtures` and `utils` had to be moved out of the `test` cfg, so they
can be imported from tvix-store.
- Some ad-hoc fixtures in the test were moved to proper fixtures in the
same step.
- The protos are now created by a (more static) recipe in the protos/
directory.
The (now two) golang targets are commented out, as it's not possible to
update them properly in the same CL. This will be done by a followup CL
once this is merged (and whitby deployed)
Bug: https://b.tvl.fyi/issues/301
Change-Id: I8d675d4bf1fb697eb7d479747c1b1e3635718107
Reviewed-on: https://cl.tvl.fyi/c/depot/+/9370
Reviewed-by: tazjin <tazjin@tvl.su>
Reviewed-by: flokli <flokli@flokli.de>
Autosubmit: flokli <flokli@flokli.de>
Tested-by: BuildkiteCI
Reviewed-by: Connor Brewster <cbrewster@hey.com>
|